Field Service Ver. 8.0 Jun. 2008
E. XPS Settings
3
• This is displayed only when the function enhanced version 2 or later firmware is installed.
(1) Verify XPS Digital Signature
Functions
• Selects whether to verify digital signatures attached to XPS (XML Paper Specifica-
tion) files when printing the files.
Use
• When digital signature verification is selected, files with invalid digital signatures are
not printed.
Setting/
• The default setting is OFF.
Procedure
F. Print Reports
• It will not be displayed when the following setting shows that authentication device 1 or
vendor is mounted.
[Service Mode] → [Billing Setting] → [Management Function Choice]
(It will be displayed when the key counter is mounted.)
Functions
• To output the report or demo page concerning the print setting.
Use
• To check the setting concerning the printer.
The types of report available for output are as follows.
Configuration Page : The list of printer setting will be output.
Demo Page
PCL Font List
PS Font List
1. Touch [User Setting] → [Printer Setting] → [Print Reports].
Setting/
Procedure
2. Select the report to be output.
3. Select the feed tray.
4. Select Simplex or Duplex print, and touch the Start key.
8.5.6

Change Password

• When conducting user authentication (MFP only), it will be displayed only when the
authentication is complete.
• This menu is available only when box administrator authentication is established during
user authentication or account track.
Functions
• To modify the password used for the user authentication.
Use
• To modify the user authentication password currently used.
Setting/
• Enter the user authentication password with the keys on the control panel.
Procedure
Current Password : Enter the user authentication password currently used.
New Password
Retype Password
NOTE
• When [Password Rules] which can be displayed by the following setting is set
to "ON", password using the single letter or the password same with the previ-
ous one, less than 8-digit will not be modified.
[Utility] → [Administrator Settings] → [Security Setting]
• When the following setting is set to "ON", entering the incorrect password
three times will cause access lock. When an access lock occurred, turn the
main power switch OFF, and wait for 10 seconds or more and turn main power
switch ON again to enter the password again.
[Administrator Settings] → [Security Setting] → [Enhanced Security Mode]
ON
: The test page will be output.
: PCL font list will be output.
: PS font list will be output.
: Enter the new user authentication password to be used.
: Enter the new user authentication password again.
8. Utility Mode
"OFF"
317