6. Other
[2]
[1]
[2]
[2]
226
[1]
A00JF2C333DA
A00JF2C334DA
[1]
A00JF2C335DA
Field Service Ver. 8.0 Jun. 2008
7. Disconnect the connector [1].
8. Remove the harness from four wire
saddles [2].
9. Remove four screws [1], and take out
the fan motor assy/4 [2] as clearing
the harness.
10. Remove two connectors [2] on the
high voltage unit/2 [1].