Setting The Register Conditions For Edge Detection - Sharp IV-C35M User Manual

Compact color image sensor camera
Hide thumbs Also See for IV-C35M:
Table of Contents

Advertisement

MATCH LVL (CONTR)
Specify the degree of match used for detection
in the contracted images (detects contracted
shapes in images whose value is larger than the
specified reference value).
MATCH LVL
Specify a degree of match used for detection in
the original images of the contracted images that
were detected in the search at line "
LVL" (detects original images which are larger
than the specified value).

[2] Setting the register conditions for edge detection

MEAS SHAPE
Select a measurement shape.
RECTANGLE
(NO ARTF)
RECTANGLE
(ARTIF)
LINE (straight line)
CIRC-L (circle)
ELIP-L (ellipse)
NO ARTF/ARTIF: Select whether to detect edge
MATCH
Select a pattern to be used
for image processing.
See pages 3-15 to 3-19.
or not with average density.
See page 3-26.
15-7
Multiple Positional Measurement
REG COND
SCREEN COND SAVE DETAIL
1
0(0 3)
2REFERENCE IMG
015(000~026)
3REF-IMG AREA
SET (224.208) (287.271)
4SEARCH AREA
SET (216.200) (295.279)
5DIRECT COORD
CENTER (234.219)
6CONTR.PIXEL
3
7MATCH LVL(CONTR)
+05000
8MATCH LVL
+07000
SEL=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
REG COND
SCREEN COND SAVE
1
0(0 3)
2MEAS SHAPE
RECTANGLE (NO ARFT)
3SEARCH AREA
SET (224.208) (287.271)
4DTECT MODE
CHNG POINT
5SEARCH DIRECT
HORIZ (
6THRESHOLD
SET (D:050 E:2 F:04)
SEL=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
RED F C1 BRT
RED F C1 BRT
RECTANGLE (NO ARTF)
RECTANGLE (ARTIF)
LINE
CIRC-L
ELIP-L
CHNG POINT
DRK
DRK
CENT(
CENT(DRK
HORIZ (
HORIZ (

Advertisement

Table of Contents
loading

Table of Contents