Color Unevenness Inspection
Set the evaluation conditions
How to move to the evaluation condition setting screen
There are two methods for getting to the evaluation condition setting screen.
1) Select "COND" in the upper function menu on
the MEAS COND (or REG COND) screen and
press the SET key. Select "EVALUATION" on
the pop up menu to go to the EVALUAT COND
screen.
2) Move the cursor to the "EVALUATION COND"
item on the menu tree screen and press the
SET key.
12
The "EVALUAT COND" (evaluation conditions)
screen will appear.
For details about the evaluation conditions,
see page 3-28.
MEA-CND
SCREEN COND SAVE
1REGISTER
2REFERENCE COLOR
3MEAS SHAPE
4MEAS AREA
5BOUNDARY PROCESS VALID
6AREA FILTER
=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POP UP
EVALUAT COND
SCREEN COND SAVE EDIT SEL
1REGISTER NO.
2CONDITION SET
3NUMBER OF OBJ
4TOTAL AREA
5OBJECT AREA
6HUE
7NO. OF HUE FAULT
8CHROMA
9NO. OF CHROMA FAULT
0TEST
=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
12-6
RED F C1 BRT
REG COND
NO.0
0 (0 7)
EVALUATION
RECTANGLE
NUM-CALC
SET (224, 208) (287, 271)
OUT
U. LM245760 L. LM000000
(0 245760)
1REGISTER NO.
2CONDITION SET
3NUMBER OF OBJ
4TOTAL AREA
5OBJECT AREA
6HUE
7NO. OF HUE FAULT
8CHROMA
9NO. OF CHROMA FAULT
0TEST
COLOR F C1 BRT
0 (0 3)
[TEST RESULT]
[OUTPUT]
AUTO (±10%)
000
128
K=
NO
00000
245760 A=
NO
00000
245760 R=
NO
000.0
359.9
H=
NO
00000
245760 EH=
NO
000.0
359.9
S=
NO
00000
245760 ES=
NO
EXEC (WITH-POSI. ADJ WITHOUT-POSI. ADJ)