Sharp IV-C35M User Manual page 146

Compact color image sensor camera
Hide thumbs Also See for IV-C35M:
Table of Contents

Advertisement

Set the evaluation conditions
How to move to the evaluation condition setting screen
There are two methods for getting to the evaluation condition setting screen.
1) Select "COND" in the upper function menu
on the "MEAS CND" (or "REG COND")
screen and press the SET key. Select
"EVALUATION" on the pop up menu to go
to the "EVALUAT COND" screen.
2) Move the cursor to the "EVALUATION
COND" item on the menu tree screen and
press the SET key.
The "EVALUAT COND" (evaluation conditions)
screen will appear.
For details about the evaluation conditions,
see page 3-28.
MEAS CND
SCREEN COND SAVE
1REGISTER NO.
00(0 15)
2REGISTER EXIST YES
3DTECT PRECISION STANDARD
REGISTER NO.
4MEAS OBJECT
LEAD LENGTH
IMG PRE-PROC
REG-COND
EVALUATION
NUM-CALC
OUT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND (CAMERA1)
MEAS0
POSI-CORRECT
MEAS01 (INSPECT-LEAD F)
IMG PRE-PROC
MEAS CND
EVALUATION COND
NUM-CALC
OUT-COND
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
EVALUAT COND SCREEN COND SAVE EDIT SEL
1REGISTER NO.
00(0~15)
2CONDITION SET
AUTO( 10%)
3NUMBER OF OBJ
000~128
4DISTANCE
000.0~702.0
5LEAD WIDTH
000.0~702.0
6LEAD LENGTH
000.0~702.0
7TEST
EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
6-7
Lead Inspection
RED F C1 BRT
COLOR F C1 BRT
1REGISTER NO.
2CONDITION SET
3NUMBER OF OBJ
4DISTANCE
5LEAD WIDTH
6LEAD LENGTH
7TEST
OBJECT TYPE COND
RED F C1 BRT
[TEST RESULT]
[OUTPUT]
K=
NO
D=
NO
W=
NO
L=
NO
6