Object Counting by Binary Conversion
How to set the register conditions
How to enter the REG-COND setting screen
There are three methods for getting to the REG-COND setting screen.
1) On the "MEA-CND" setting screen, move the
cursor to the "
press the SET key. The cursor will move into
the table. Move the cursor to the " " column
and press the SET key.
Note: If you press the SET key in the "X"
2) On the "MEA-CND" setting screen, press the
TRG/BRT key to move the cursor to the upper function menu. Select the "COND" item and then
select the "REG COND" item and press the SET key.
9
3) On the menu tree, move the cursor to the
"MEAS CND" item, and press the right arrow
key. The sub menu which contains the "REG
COND" item will appear. Move the cursor to
this item and press the SET key.
REGISTER NO.
The currently selected register number is
displayed.
If you want to set the measurement
conditions for a different register number,
press the SET key to highlight the register
number currently selected. Then press the up
and down arrow keys to select the register
number whose measurement conditions you
want to set. Press the SET key to confirm
your selection.
Note: When the "BINARY-IMG-MASK" or the
MEA-CND
1MEAS SHAPE
2MEAS AREA
3THRESHOLD
4INVERT B/W
BIN AREA COND" and
column, the setting will be invalid.
"POLYGON" is selected at
"
WINDOW" on the "MEA-CND"
screen, the "
REGISTER NO." line
will not be displayed and the other item
numbers are decrement by one since
the register number for "BINARY-IMG-
MASK" and "POLYGON" is fixed.
MEA-CND
SCREEN COND SAVE
1
NORMAL
2REGISTER NO.
0(0 3)
3REGISTER EXIST YES
REGISTER NO.
4BIN AREA COND
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE01
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-DEVIATION
MEAS01(CNT-BIN-OBJ F)
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
REG COND
SCREEN COND SAVE DETAIL
1REGISTER NO.
2MEAS SHAPE
RECTANGLE
3MEAS AREA
SET (224,208) (287,271)
4THRESHOLD
SET [U.LM255 L.LM100 (0~255)]
5INVERT B/W
NO
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
9-4
RED F C1 BRT
IMG PRE-PROC
REG COND
EVALUATION
NUM-CALC
OUT
COLOR F C1 BRT
1REGISTER NO.
2MEAS SHAPE
3MEAS AREA
4THRESHOLD
5INVERT B/W
IMG PRE-PROC
MEAS CND
REG COND
EVALUATION COND
NUM-CALC
OUT-COND
RED F C1 BRT
RECTANGLE
CIRCLE
ELLIPSE
NO
YES