Output Block Assignment (Computer Link Output And General Purpose Serial Output); Data In Specified Blocks - Sharp IV-C35M User Manual

Compact color image sensor camera
Hide thumbs Also See for IV-C35M:
Table of Contents

Advertisement

21-6 Output block assignment (Computer link output and general
purpose serial output)
When measurement is controlled by a computer link or a communication interface (general purpose
serial IF: * 1), in addition to other block 0, blocks can be specified whose measurement data will be
output from the IV-C35M to a programmable controller or a personal computer.
* 1 In the case of a communication interface (general purpose serial IF), output blocks can be
specified only when the measurement is started by a CCD trigger or a parallel IF signal and the
results are set by a general purpose serial IF signal.
Specify the settings above on the "OBJ-TYPE I/O" screen

[1] Data in specified blocks

(1) In the case of a computer link
Data in the specified blocks will be output after the data (block 0) from measurement numbers 0 to 4
is output by the write register of the PC.
Write register map
Result top write
address (* 2)
Result top write
address
+ 512 bytes
(* 3)
* 2 Set the result top write address in item "
See the preceding page.
* 3 The top address to which the data in the specified blocks will be written is obtained by adding 512
bytes to the result top write address.
- Setting examples for various manufacturers
Result top write
address
Top address of data
in specified blocks
See page 23-3.
Sharp Mitsubishi
OMRON
09000
L
D0000
DM0000
H
09001
L
H
L
H
WRITE TOP ADRS" on the "COMPUTER LINK" screen.
Sharp
Mitsubishi OMRON Yokogawa
09000
09300
D0000
19000
19300
D0256
21-25
Setting the Input/Output Conditions
See page 22-3.
See the next page.
Yokogawa
Termination code
L
L
D00001
H
H
Appended information
L
L
Output data from measurement No. 3
(block 0)
H
H
Data in a specified block
L
L
H
H
DM0000 D00001
DM0256 D00257
Description