Positional Deviation Measurement
Set the evaluation conditions
How to move to the evaluation condition setting screen
There are two methods for getting to the evaluation condition setting screen.
1) Select "COND" in the upper function menu on
the MEAS COND (or REG COND) screen
and press the SET key. Select
"EVALUATION" on the pop up menu to go to
4
the EVALUAT COND screen.
2) Move the cursor to the "EVALUATION COND"
item on the Menu tree screen and press the
SET key.
The "EVALUAT COND" (evaluation conditions)
screen will appear.
For details about the evaluation conditions, see
page 3-28.
MEAS CND
SCREEN COND SAVE
1DTECT PRECISION STANDARD
2
0(0 7)
3
1P-SCH
4DTECT ANGL
NO
5ANGLE UNIT
6
7
SET=SELECT A MENU FOR ESC=BACK SEL=CHNG IMG TRG=FUNC
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0(POSI-DEVIATION F)
IMG PRE-PROC
MEAS CND
EVALUATION COND
DISTANCE&ANGLE COND
NUM-CALC
OUT-COND
POSI-CORRECT
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
EVALUAT COND SCREEN COND SAVE EDIT SEL
1REGISTER NO.
2CONDITION SET
3X COORD.(MDL0)
4Y COORD.(MDL0)
5x DEVAITE(MDL0)
6y DEVAITE(MDL0)
7MATCH LVL(MDL0)
8TEST
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
4-10
BLUE
F C1 BRT
IMG PRE-PROC
REG-COND(S)
REG-COND(E)
EVALUATION
DST&ANGL
NUM-CALC
OUT
COLOR
F C1 BRT
1REGISTER NO.
2CONDITION SET
3X COORD.(MDL0)
4Y COORD.(MDL0)
5x DEVAITE(MDL0)
6y DEVAITE(MDL0)
7MATCH LVL(MDL0)
8TEST
REG-COND(S)
REG-COND(E)
BLUE
F C1 BRT
0(0~7)
[TEST RESULT]
[OUTPUT]
AUTO(–10%)
000.0~511.0
X0=
NO
000.0~479.0
Y0=
NO
-511.0~+511.0
x0=
NO
-479.0~+479.0
y0=
NO
-10000~+10000 M0=
NO
EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)