Lead Inspection
3) On the menu tree, move the cursor to the
"MEAS CND" item, and press the right
arrow key. The sub menu which contains
the "REG COND" item will appear. Move
the cursor to either of these items and press
the SET key.
6
Set the register conditions
REGISTER NO.
The currently selected register number is
displayed.
If you want to set the measurement
conditions for a different register number,
press the SET key to highlight the register
number currently selected. Then press the
up and down arrow keys to select the
register number whose measurement
conditions you want to set. Press the SET
key to confirm your selection.
DTECT SHAPE
Select a detection shape. Three shapes
are available: "RECT(ARTIFACT)," "LINE,"
and "CIRC-L." Depending on which item is
selected, the choices on lines "
AREA" and "
change.
RECT
(ARTIFACT)
LINE
CIRC-L
SEARCH AREA
Specify a search area. Move the cursor to this line and press the SET key. The currently SET
item will be highlighted. Press the SET key again to enter the setting screen.
When the "RECT (ARTIFACT)" is selected
SEARCH DIRECT" will
Specify the coordinates of the upper left and lower right corners. The controller
will detect an edge inside this rectangle. For details about processing artifacts,
see page 3-26.
Specify the coordinates of the starting and end points. The controller will
detect an edge along this straight line.
Specify the coordinates of the center and radius. The controller will detect an
edge inside this circle.
Specify the upper left and lower right corners
of the rectangular search area.
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND (CAMERA1)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
REG COND
1REGISTER NO.
2DTECT SHAPE
3SEARCH AREA
4DTECT MODE
5SEARCH DIRECT HORIZ( )
6THRESHOLD
7EXTENSION
8EXT.MEAS DIRECT VERTY=+000
SEARCH
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
UP.L
6-4
COLOR F C1 BRT
1REGISTER NO.
2DTECT SHAPE
3SEARCH AREA
4DTECT MODE
5SEARCH DIRECT
MEAS0
6THRESHOLD
POSI-CORRECT
MEAS01 (INSPECT-LEAD F)
IMG PRE-PROC
MEAS CND
REG-COND
EVALUATION COND
NUM-CALC
OUT-COND
MEAS(NEW)
SCREEN COND SAVE DATAIL
RED F C1 BRT
RECT(ARTIFACT)
00(0 15)
LINE
RECT(ARTIFACT)
CIRC-L
SET(224,208) (287,271)
CENT(BRT)
SET(D:050 E:2 F:04)
LEAD-LENGTH
HORIZ
HORIZ
VERT
VERT
NO
LEAD-LENGTH
BALL-WIDTH
LO.R
CENT(BRT)
CENT(DRK)