Input & Output / System Settings; Illuminance (Light Level) Monitor - Sharp IV-C35M User Manual

Compact color image sensor camera
Hide thumbs Also See for IV-C35M:
Table of Contents

Advertisement

Setting Measurement Conditions
3-3 Input & Output / System settings

[1] Illuminance (light level) monitor

(1) Purpose
1. Allows the system to monitor changes the lighting of the environment
If the light level exceeds the preset lighting range, it will be regarded as a change in the
environment and "OVR ILLM RANGE" will be displayed on the MAIN OPS MENU.
3
2. Automatic adjustment of the threshold values used for binary conversions can follow
changes in the lighting environment.
The threshold value is modified from the user's setting due to changes in the actual brightness
measured in the environment.
(2) Applications
Used when the level of illumination changed due to changes in voltage or when the influence of
sunlight in the workplace cannot be ignored.
(3) Setting procedure
Select "OBJECT TYPE COND" > "TYPE00" (current type) and "OBJ-TYPE SYS," in that order, on the
"MAIN MENU" screen.
1. Select "
light level). Select "YES" from the popup menu.
Then, the "
appear on the screen.
2. Select "
key. The "LIGHT LV COND" screen and
monitoring window will appear.
3. Press the SEL key and move the cursor to the
upper function menu. Set the image mode to
"T" (Through).
MNTR LIGHT LVL (CAM1)" (monitor
LIGHT LV COND" item will
LIGHT LV COND" and press the SET
OBJ-TYPE SYS. SCREEN SAVE
1REGST NG IMG
NO
2HALT ON NG MEAS
YES
3MNTR LIGHT LVL(CAM1) YES
4LIGHT LV COND
(TO NEXT SUB-BENU)
5MNTR LIGHT LVL(CAM2) YES
6LIGHT LV COND
(TO NEXT SUB-MENU)
7MOVE ALL WINDOW
(TO NEXT SUB-MENU)
LIGHT LV COND SCREEN SAVE
1SIZE
Y08(4~32)X08(4~65)
2POSITION
(248,232)
3THRESHOLD VALUE U.LM255 L.LM000(0~255)
4REG AVG.GRAY LV
EXEC REG.AVG.GRAY=000.0
Monitor window
SEL=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
3-48
RED F C1 BRT
NO
YES
RED F C1 BRT
MEAS.AVG.GRA=000.0

Advertisement

Table of Contents