Sharp IV-C35M User Manual page 152

Compact color image sensor camera
Hide thumbs Also See for IV-C35M:
Table of Contents

Advertisement

* When the "BINARY-IMG-MASK" or the
"POLYGON" is selected at
"
WINDOW" on the "MEA-CND"
screen, the "
REGISTER NO." line will
not be displayed and the other item
numbers are decrement by one since the
register number for "BINARY-IMG-MASK"
and "POLYGON" is fixed.
MEAS SHAPE
Specify shape of measuring range.
Specify the coordinates for the upper left and lower right corners.
RECTANGLE
The measurement area will be the area enclosed by this rectangle.
Specify the center and the radius. The measurement area will be the
CIRCLE
area enclosed by this circle.
Specify the center and the radius. The measurement area will be the
ELLIPSE
area enclosed by this ellipse.
MEAS AREA
Specify a search area.
When "RECTANGLE" is selected
Specify the upper left and lower right corners of the
rectangular search area.
When "CIRCLE" is selected
Specify the center and the radius.
When "ELLIPSE" is selected
Specify the center and the
radius.
REG COND
SCREEN COND SAVE DETAIL
1MEAS SHAPE
RECTANGLE
2MEAS AREA
SET (224,208) (287,271)
3THRESHOLD
SET [U.LM255 L.LM100 (0~255)]
4INVERT B/W
NO
5NUM. OF DTECT X00 Y00 (0~64)
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
UP.L
Center
Center
7-5
BGA/CSP Inspection
RED F C1 BRT
LO.R
Radius
Radius
7