Numeric calculation setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using
the left and right arrow keys. Press the SET key to show the popup menu. Select "NUM-CALC" from
the popup menu.
- Select "NUM-CALC" on the menu tree.
See "Chapter 19: Numerical calculation."
Output condition setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using
the left and right arrow keys. Press the SET key to display the popup menu. Select "OUT" from the
popup menu.
- Select "OUT-COND" on the menu tree.
See "Chapter 21: Setting the Input/Output Conditions."
Display the measurement results
Return to the operation screen and press the TRG/BRT key. The measurement results will be dis-
played on the screen.
Final evaluation result
Measuring time
Measurement program
Registration number in
the measurement condition
NUMBER OF OBJECTS
TOTAL AREA
LABEL NUMBER
- CENT OF GRAV, MAIN AXIS
ANGL, FILLET WIDTH,
PERIPHERAL, or MID POINT are
displayed when measurement of
these parameters has been
specified ("YES" has been
selected) on the "MEAS COND"
menu (page 10-2).
OBJECT AREA
CENTER OF GRAVITY
CORDINATE
MAIN AXIS ANGLE
FILLET DIA
PERIPHERAL
10-9
Object Identification by Binary Conversion
(TYPE00)
OK
MEAS XXXXms 2001-10-14 10:38
MEASUREMENT 1 LABEL-BIN-OBJ
REGISTER NO.0(0~3)
K=004
OK
A=006168
OK
LABEL NUMBER 000 000 003
R=001542
OK
GX=206.0
OK
GY=303.0
B= 028.0
FX=042
FY=037
CR=00138.8
CX=
CY=
X0 7
Y0 7
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE