Figure 2-38 No Answer Display - NEC Univerge SV8100 Features And Specifications Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
If the VRS message is not recorded, a tone is provided.
Emergency call destination must be set considering this feature's purpose.
The emergency number dialed does not follow ARS settings:
If Program 13-01-01 is set to Trunk the system uses command Program 13-05 to route the
emergency call.
If Program 13-01-01 is set to ICM the system uses command Program14-06 to route the
emergency call.
If remote inspection target does not answer, display below sentence to terminal which set
Program 20-08-24 data to 1.
Press Exit, display returns to idle.
Emergency Call 1
Emergency calls when Security Sensor or Remote Inspection performed, SMDR can record
these call class as follows:
Security Sensor: SAD
Remote Inspection: WAD
Emergency Call 2
When Security Sensor or Remote Inspection performs an Emergency call, alarm reports are
recorded and the alarm display terminal indicates the following:
Security Sensor: 31: Sensor Detect
Remote Inspection: 32: Confirm Dial
Recording Emergency Call
By setting Program 90-20-11 (1; Report) Emergency calls can be recorded on security report.
Maximum of 50 records can be saved.
Security

Figure 2-38 No Answer Display

Issue 11.0
2 - 1293