Issue 11.0
Remote Inspection
<Program>
Program 11-10-49: (619) Auto Dial Setting for Remote
Program 20-45-01: (200) Remote Inspection terminal, 200
Program 20-45-02: (12:00) Ringing start time, 12 o'clock noon
Program 20-45-03: (3) ringing continue time, 3 minutes
Program 20-45-04: (1999) Speed dial bin number, 1999
Program 20-45-05: (1) VRS message number when inspected extension answered, 1
Program 20-45-06: (2) VRS message number when emergency call destination answered, 2
Program 20-45-07: (3) Times of auto repeat dial, 3
Program 20-45-08: (30) Auto dial calling time, 30 sec
Program 20-45-09: (30) Interval of Auto Dial, 30 sec
Set Up Remote Inspection
1.
Press Speaker and dial 619.
2.
Dial the Remote Inspection terminal number (1-6).
3.
Dial 1 to set.
4.
Dial the Remote Inspection extension number, 200.
5.
Dial the Ring start time, 1200.
6.
Dial ring length time, 03.
7.
Dial the Speed dial bin number to be used, 1999.
8.
Dial the emergency call destination number xxx-xxx and press Hold.
9.
When answered, dial the VRS message number 001.
10.
After the beep, record the message and press
11.
When the emergency call destination answers, dial VRS message2
12.
After confirmation tone, record message.
13.
Press Speaker to hang up.
Cancel the Remote Inspection
1.
Press Speaker and 619.
2.
Dial the Remote Inspection number (1-6).
3.
Dial 0 to cancel.
2 - 1304
.
#