NEC Univerge SV8100 Features And Specifications Manual page 1179

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
80-04-04
Call Progress Tone Detector
Setup – No Tone Time
82-11-01
LCA Initial Setup – Bounce
Protect Time
82-11-02
LCA Initial Setup – HookFlash
Start Time
82-11-03
LCA Initial Setup – HookFlash
End Time
Refer to
Single Line Telephones, Analog 500/2500 Sets on page 2-1321
Operation
Normal call handling procedures for single line telephones apply.
(OPX) Off-Premise Extension
Description/Comments
Define the no tone time for the Call
Progress Tone Detector.
Specify a time for detection of a
valid 0ff-Hook indication that is
long enough to prevent an
unintentional bounce of the
receiver from being detected as a
new off-hook indication from a
single line telephone.
Specify the minimum hookflash
time from a Single Line Telephone
or analog Voice Mail system
before it is detected as the
beginning of a valid hookflash.
Specify the maximum hookflash
duration from a Single Line
Telephone to receive a second
dial tone.
Assigned Data
1
0~255
(30+30-7680ms)
The formula is 30+30N.
When set to N=1, it
means 30+30*1=60
When set to N=255, it
means
30+30*255=7680
(0 =not detect)
default:
Type 1 (DT) – 132
(3990ms)
Type 2 (BT) – 132
(3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0
0 = No Setting
1~15 = 100ms~1.5sec
(default = 3)
0 = 40ms
1~15 = 90ms~790ms
(default = 5)
0 = HST+0ms 1~15 =
HST+100ms~HST+15
00ms
(HST=Hookflash Start
Time)
(default = 7)
for related programming.