Section 2: Installation and Setup
ArtNet INTERFACE SETTINGS:
information about ArtNet settings.

2.6.3 Separating Networks

By default, communications originating from 1 type of serial controller (RS-232 vs. RS-422 vs. Ethernet) stays
on the corresponding network path. A "Separate" setting indicates this separation for "Network Routing" in the
Communications
projector to which it is connected unless you change this setting to either "RS-232 and RS-422 Joined" or "All
Joined". See
Figure

2.6.4 Communicating to All Ports

To relay all messages to all ports (RS-232, RS-422, and Ethernet) set the "Network Routing" option in the
Communications menu for each projector to "All Joined". This configuration is useful if you are using a non-
RS-232 controller with the RS-232 linking available between these projectors. For example, you may want to
use both an RS-422-compatible controller, and an Ethernet-connected PC for working with a network of
projectors linked via their RS-232 in/out ports. Refer to
To isolate just RS-422 communications, select "RS-232 and Ethernet Joined". In
#3 will respond to the RS-422 controller. To isolate just Ethernet communications, select "RS-232 and RS-422
Joined". Only projector #1 will respond via Ethernet.
2-28
Refer to
Section 3.6.2 System Configuration (Communication)
menu. If you are using an RS-422 controller, for example, it will communicate only with the
2-39.
Figure 2-39 Keeping Communications Separate (default)
Figure 2-40 Joining All Networks
Figure
2-40.
Roadster, Matrix WU, Mirage S+/HD/WU User Manual
for additional
Figure
2-40, only projector
020-100002-06 Rev. 1 (04-2011)