5 Troubleshooting
If the projector does not appear to be operating properly, note the symptoms present and use the following
guide to assist you. If you cannot resolve the problems yourself, contact your dealer for assistance.
A Christie accredited service technician is required when opening an enclosure to diagnose any
NOTE:
"probable cause".
5.1

Displays

5.1.1 Blank screen, no display of image

1. Confirm all power connections are still OK.
2. Ensure the lens cap has been removed.
3. Ensure the shutter is OPEN.
4. Ensure a full black test pattern has not been selected for display. Press
patterns, then cycle patterns with the
5. Is the input selected? Check connections.

5.1.2 Blacklevels seem too high

Reduce Brightness setting.

5.1.3 Image appears "squeezed" or vertically stretched into center of screen

1. Check your Resizing selection.
2. The anamorphic lens (optional) may be needed for this source.

5.1.4 The projector is ON but there is no display

1. Was a lens cover accidentally left on? Remove lens cover.
2. Ensure the shutter is OPEN.
3. Is the lamp ignited? Check for interlock problems such as an open lamp door.
4. Is the correct input selected?
5. Is the source connected properly? Check the cable connections and ensure the correct source is selected.
6. Is the AC power connected?
7. Can you access test patterns? If so, check your source connections again.
Roadster, Matrix WU, Mirage S+/HD/WU User Manual