Line - TP-Link JetStream T3700G-28TQ Reference Manual

Jetstream 28-port gigabit stackable l3 managed switch
Hide thumbs Also See for JetStream T3700G-28TQ:
Table of Contents

Advertisement

T3700G-28TQ
JetStream 28-Port Gigabit Stackable L3 Managed Switch CLI Guide
Parameter
minutes ——The timeout time, ranging from 5 to 30 in minutes. The value is 10
by default.
Command Mode
Global Configuration Mode
Example
Configure the timeout time of the switch as 15 minutes:
T3700G-28TQ(config)#user idle-timeout 15

line

Description
The line command is used to enter the Line Configuration Mode and make
related configurations for the desired user(s), including the login mode and
password configurations.
Syntax
line [console linenum | vty startlinenum endlinenum ]
Parameter
linenum —— The number of users allowed to login through console port. Its
value is 0 in general as there is only one console port on a switch.
startlinenum ——The start serial number of the login user selected to configure
the login mode and password, ranging from 0 to 15. 0 means the first login user
number, 1 means the second, and the rest can be done on the same manner.
endlinenum —— The end serial number of the login user selected to configure
the login mode and password, ranging from 0 to 15. 0 means the first login user
number, 1 means the second, and the rest can be done on the same manner.
Command Mode
Global Configuration Mode
Example
Enter the Console port configuration mode and configure the console port 0:
T3700G-28TQ(config)#line console 0
76