TP-Link JetStream T2600G-18TS Installation Manual

Gigabit l2 managed switch
Hide thumbs Also See for JetStream T2600G-18TS:

Advertisement

Business Networking Solution
Installation Guide
JetStream Gigabit L2 Managed Switch
T2600G-18TS (TL-SG3216)
T2600G-28TS (TL-SG3424)
T2600G-52TS (TL-SG3452)
T2600G-28MPS (TL-SG3424P)

Advertisement

Table of Contents
loading

Summary of Contents for TP-Link JetStream T2600G-18TS

  • Page 1 Business Networking Solution Installation Guide JetStream Gigabit L2 Managed Switch T2600G-18TS (TL-SG3216) T2600G-28TS (TL-SG3424) T2600G-52TS (TL-SG3452) T2600G-28MPS (TL-SG3424P)
  • Page 3 • Some models featured in this guide may be unavailable in your country or region. For local sales information, visit http://www.tp-link.com. • The figures in Chapter 2 to Chapter 5 are for demonstration purposes only. Your switch may differ in appearance from that depicted.
  • Page 4: Table Of Contents

    JetStream Gigabit L2 Managed Switch Contents Chapter 1 Introduction ——————————— 01 Product Overview ..........01 Appearance ............01 Chapter 2 Installation ——————————— 07 Package Contents ..........07 Safety Precautions ..........07 Installation Tools ...........09 Product Installation ..........09 Chapter 3 Lightning Protection ——————— 11 Cabling Reasonably ..........11 Connect to Ground ..........13 Chapter 4 Connection ———————————...
  • Page 5: Chapter 1 Introduction

    Designed for workgroups and departments, T2600G-18TS/T2600G-28TS/T2600G-52TS/T2600G- 28MPS from TP-Link provides wire-speed performance and full set of L2 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks.
  • Page 6 JetStream Gigabit L2 Managed Switch The front panel of T2600G-28TS is shown as the following figure. Figure 1-2 Front Panel of T2600G-28TS T2600G-28TS SFP Port Console Console 10/100/1000Mbps LEDs (RJ45) (USB) RJ45 Port LEDs Status Indication The switch is powered on. The switch is powered off or power supply is abnormal.
  • Page 7 JetStream Gigabit L2 Managed Switch The front panel of The T2600G-52TS is shown as the following figure. Figure 1-3 Front Panel of T2600G-52TS Console(USB) Console Console Console LEDs 10/100/1000Mbps SFP Port (USB) (RJ45) RJ45 Port Console (USB) Port Designed to connect with the USB port of a computer for monitoring and configuring the switch. The switch has an RJ-45 console port and a micro-USB console port available.
  • Page 8 JetStream Gigabit L2 Managed Switch SFP Port Designed to install the SFP module. T2600G-52TS features 4 individual SFP ports and supports 1000M SFP module connection only. The front panel of The T2600G-28MPS is shown as the following figure. Figure 1-4 Front Panel of T2600G-28MPS LEDs Console...
  • Page 9 JetStream Gigabit L2 Managed Switch LEDs Status Indication The switch is powered on. The switch is powered off or power supply is abnormal. Flashing Power supply is abnormal. Flashing The switch works properly. On/Off The switch works improperly. The remaining PoE power≤7W. The remaining PoE power keeps≤7W after this LED is on for 2 PoE Max Flashing...
  • Page 10 JetStream Gigabit L2 Managed Switch Port Feature Model 10/100/1000Mbps RJ45 Port SFP Port Console Port T2600G-18TS T2600G-28TS T2600G-52TS T2600G-28MPS Rear Panel ■ The rear panel of the switch is shown as the following figure Figure 1-5 Rear Panel 100-240V~50/60Hz 0.5A Kensington Grounding Power...
  • Page 11: Chapter 2 Installation

    JetStream Gigabit L2 Managed Switch Chapter 2 Installation Package Contents Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Power Cord, One Console This Installation Guide One Switch Cable and One USB Cable One Resouce CD...
  • Page 12 JetStream Gigabit L2 Managed Switch Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device.
  • Page 13: Installation Tools

    JetStream Gigabit L2 Managed Switch enough to damage electronic devices, more effective lightning protection measures should be taken. Ensure the rack and device are well earthed. ■ Make sure the power socket has a good contact with the ground. ■ Keep a reasonable cabling system and avoid induced lightning.
  • Page 14 JetStream Gigabit L2 Managed Switch Figure 2-1 Desktop Installation Feet Bottom of the Device Notch Rack Installation ■ To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below: 1. Check the grounding and stability of the rack. 2.
  • Page 15: Chapter 3 Lightning Protection

    JetStream Gigabit L2 Managed Switch Chapter 3 Lightning Protection Cabling Reasonably In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices.
  • Page 16: Requirements For Cabling Indoors

    JetStream Gigabit L2 Managed Switch Requirements for Cabling Indoors ■ When cabling indoors, keep a certain distance away from the devices that may cause high- frequency interferences, such as down-conductor cable, powerline, power transformer and electromotor. The main cable should be paved in the metal raceway of the access shaft. When cabling, keep the ■...
  • Page 17: Connect To Ground

    JetStream Gigabit L2 Managed Switch Device Min Distance (m) Switch case 1.00 Transformer room 2.00 Elevator tower 2.00 Air-conditioner room 2.00 Connect to Ground Connecting the device to ground is to quickly release the lightning over-voltage and over-current of the device, which is also a necessary measure to protect the body from electric shock. In different environments, the device may be grounded differently.
  • Page 18 JetStream Gigabit L2 Managed Switch Connecting to the Ground via the Grounding Terminal ■ Use the grounding bar If the device is installed in the Equipment Room, where a grounding bar is available, you are recommended to connect the device to the grounding bar as shown in the following figure. Figure 3-1 Connecting to the Grounding Bar Switch (Rear Panel)
  • Page 19 JetStream Gigabit L2 Managed Switch When equipotential bonding, please note that the cable should be copper wrapped Kelly with its area being 6mm at least. The shorter cable the better, and use a grounding bar to establish an equipotential bonding point. Note: The equipotential bonding cable and ground cable are not provided with our product.
  • Page 20: Chapter 4 Connection

    JetStream Gigabit L2 Managed Switch Chapter 4 Connection Ethernet Port Connect an Ethernet port of the switch to the computer by RJ45 cable as the following figure shows. Figure 4-1 Connecting the RJ45 Port RJ45 Port RJ45 Cable SFP Port Figure 4-2 demonstrates the connection of SFP port to an SFP module.
  • Page 21: Verify Installation

    JetStream Gigabit L2 Managed Switch Figure 4-3 Connecting the Console (RJ-45) Port Console(RJ45) Connect the Console (USB) port of the device with your computer by the USB cable as the following figure shows. Figure 4-4 Connecting the Console (USB) Port Console(USB) T260 0G-2 You can also manage the device through the console port, for details please refer to the CLI...
  • Page 22: Power On

    JetStream Gigabit L2 Managed Switch The power socket, device and rack are well grounded. ■ The device is correctly connected to other network devices. ■ Power On Plug in the negative connector of the provided power cord into the power socket of the device, and the positive connector into a power outlet as the following figure shows.
  • Page 23: Chapter 5 Configuration

    JetStream Gigabit L2 Managed Switch Chapter 5 Configuration Configure the Switch via GUI 1. To access the GUI of the switch, open a web browser and type the default management address http://192.168.0.1 in the address field of the browser, then press the Enter key. Figure 5-1 Web Browser Note: To log on to the GUI of the switch, the IP address of your PC should be set in the same subnet...
  • Page 24: Configure The Switch Using Cli

    The Micro-USB connector takes precedence over the RJ-45 connector. Install the TP-Link USB Console Driver if you are using the USB serial port for the first time on a Windows-based PC. The driver can be found on the attached CD and Download page of our official website.
  • Page 25 JetStream Gigabit L2 Managed Switch 4. Configure the terminal emulation program or the terminal. You can use the default settings as follows: Baud rate: 38400 bps ■ Data bits: 8 ■ Parity: none ■ Stop bits: 1 ■ Flow control: none ■...
  • Page 26 JetStream Gigabit L2 Managed Switch 4. Type telnet 192.168.0.1 in the command prompt shown as Figure 5-6, and press the Enter button. Figure 5-6 Connecting the Switch 5. Type the default user name and password (both of them are admin), then press the Enter button so as to enter User EXEC Mode.
  • Page 27: Appendix A Troubleshooting

    JetStream Gigabit L2 Managed Switch Appendix A Troubleshooting Q1. What could I do if I forgot the username and password of the switch? Connect the console port of the PC to the console port of the switch and open a terminal emulation program.
  • Page 28 JetStream Gigabit L2 Managed Switch Q3. What should I do if I cannot access the web management page? Please try the following: Check every port LED on the switch and make sure the Ethernet cable is connected properly. Try another port on the switch and make sure the Ethernet cable is suitable and works normally. Power off the switch and, after a while, power it on again.
  • Page 29: Appendix B Hardware Specifications

    JetStream Gigabit L2 Managed Switch Appendix B Hardware Specifications Item Content IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3z, IEEE 802.3x, IEEE 802.1p, IEEE 802.1q, IEEE 802.1x, IEEE 802.1d, IEEE 802.1s, Standards IEEE 802.1w IEEE 802.3af/at (For T2600G-28MPS only) 10Base-T: UTP/STP of Cat.
  • Page 30 FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 31 BSMI Notice 安全諮詢及注意事項 1) 請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。 2) 清潔本產品之前請先拔掉電源線。 請勿使用液體、 噴霧清潔劑或濕布進行清潔。 3) 注意防潮, 請勿將水或其他液體潑灑到本產品上。 4) 插槽與開口供通風使用, 以確保本產品的操作可靠並防止過熱, 請勿堵塞或覆蓋開口。 5) 請勿將本產品置放於靠近熱源的地方。 除非有正常的通風, 否則不可放在密閉位置中。 6) 請不要私自打開機殼, 不要嘗試自行維修本產品, 請由授權的專業人士進行此項工作。 7) 此為甲類資訊技術設備, 于居住環境中使用時, 可能會造成射頻擾動, 在此種情況下, 使用者會被要求採取某些適當的對策。 Industry Canada Statement CAN ICES-3 (A)/NMB-3(A) Explanation of the symbols on the product label Symbol Explanation AC voltage...
  • Page 32 QR code. The products of TP-Link partly contain software code developed by third parties, including software code subject to the GNU General Public License (“GPL”). As applicable, the terms of the GPL and any information on obtaining access to the respective GPL Code used in TP-Link products are available to you in GPL-Code-Centre under (http://www.tp-link.com/en/support/gpl/). The respective programs are distributed WITHOUT ANY WARRANTY and are subject to the copyrights of one or more authors.

Table of Contents