Figure 6-10 The Thermal Test - Tektronix Phaser 380 Service Manual

Hide thumbs Also See for Phaser 380:
Table of Contents

Advertisement

The Thermal Tests let you select, start and observe the operation of the printers
heaters and determine if they are operational. The test displays the real-time
temperature of active heaters. A simple graphic of a vertical bar"|" between
two brackets [.....|.......] show that the temperature is within its expected range.
If the symbol "|" is replaced by a "<" or ">" outside the bracket, the
temperature is too cold or too hot. Note that the temperature of the
cap/wipe/purge unit's heater is estimated, there is no direct temperature
sensing.

Figure 6-10 The Thermal Test

Note
For accurate thermal regulation nd measurements, the printer covers
should be in place.
Troubleshooting
Service Manual
6-33