Figure 9-15 Examining A Test Print For Margins - Tektronix Phaser 380 Service Manual

Hide thumbs Also See for Phaser 380:
Table of Contents

Advertisement

Measure this distance with
0.2 accuracy
5 mm

Figure 9-15 Examining a test print for margins

8.
Scroll to the front panel menu item Set Margin Adjustments.
9.
Scroll to the menu item Set left Margin and press Menu. Use the
arrow buttons to increment or decrement the displayed value until it
matches the value you measured for the left margin.
10. Repeat this action with the menu items Set Right Margin, Set Bottom
Margin and Set Top Margin and the corresponding margins you
measured.
11. Exit the menus.
12. Verify the calibration values by repeating Steps 4 through 10.) The left
and right margins should differ by no more than 0.4 mm from the
front panel-displayed value. Likewise, the top and bottom margins
should differ by no more than 1 mm from the front panel value.
When you exit the margin calibration menu, the new margin values are stored in
NVRAM located on the power control board.
9 mm
9 mm
Nominal
value
7 mm
Printer ID:
08:00:11:05:AD:B2
Tektronix Version:
4.40/ 4.42
TekColor Correction:
Raw CMYK Colors
Print Quality Mode:
Standard
Head Serial#:
CC30A074/ F6+
MediaType:
Letter Paper
Print Mode:
J
PS Copy Count:
1172
9 mm
Margin Check Testprint OGT2.2
9661-117
Checks and Adjustments
Service Manual
9-27
9