Figure 8-41 Removing The Media Size Sensor Board - Tektronix Phaser 380 Service Manual

Hide thumbs Also See for Phaser 380:
Table of Contents

Advertisement

Media size sensor board

Figure 8-41 Removing the media size sensor board

Tools required
Magnetic screwdriver
1.
Turn off the printer and remove the power cord.
2.
Remove the paper tray.
3.
At the rear of the printer, remove the power supply by removing the
four screws securing it in place.
4.
Remove the five screws securing the bracket to the rear printer frame.
Remove the bracket.
5.
Disconnect the wiring harness leading to the media size sensor board.
6.
Through two access holes on the lower-rear printer frame, remove the
two screws securing the media size sensor board. Slide out the board.
Disconnect
wiring harness
Bracket
Reverse these steps to install the media size sensor board.
Field Replaceable Unit Disassembly/Assembly
#2 Phillips tip
Remove
screws