REP 11.3 Sorter Control PWB
Parts List on PL 19.1
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Front Cover.
The PWB components are highly susceptible to damage from electrostatic discharge (ESD)
and extreme care should be used when handling these components. Use of the ESD Field
Service Kit is required.
NOTE: Take note of the connector positioning prior to disconnecting all connectors. This will
simplify reinstallation, later.
3.
Remove the Sorter Control PWB (Figure 1)
2
Release the PWB from
the standoffs and remove
the assembly
Figure 1 Removing the Sorter Control PWB
Replacement
1.
Perform the procedure for removal in reverse.
Repairs and Adjustments
REP 11.3
WARNING
CAUTION
1
See NOTE - Disconnect
the connectors (9)
10/00
4-130
Initial Issue
Phaser 790/DocuColor 2006