REP 9.3 ROS
Parts List on PL 5.1
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Top Cover Assembly (REP 14.4).
3.
Prepare to remove the ROS (Figure 1).
Repairs and Adjustments
REP 9.3
WARNING
1
Remove the
screws
4
Remove the
screws
Figure 1 Preparing to Remove the ROS
10/00
4-92
2
Release the har-
ness from the
clamp, then
remove the cover
3
Disconnect the con-
nectors
Initial Issue