003-333 Foreign Interface RAP

This Fault Code indicates that a communications failure was detected between the ESS PWB
and the Foreign Interface.
Procedure
Switch the IOT power off, then on. Fault Code 003-333 is still present.
Y
N
If intermittent performance is suspected, perform the following:
Check the connections between the ESS PWB and the Foreign Interface and the
interconnecting harness.
Reseat the P/J 17 connector on the ESS PWB and P/J 905 on the Foreign Interface.
Go to Flag 1 and check the wires for an open or short circuit. The wires are good.
Y
N
Repair the wires.
There is +5 VDC between J905-8 and machine frame.
Y
N
There is +5 VDC between J 17-7 and machine frame.
Y
N
Replace the ESS PWB (PL 12.1).
Go to Flag 2 and check the wire for an open circuit.
Go to Flag 3 and check the wires for an open or short circuit. The wires are good.
Y
N
Repair the wires.
Replace the ESS PWB (PL 12.1). If the problem continues, replace the Foreign Interface.