REP 8.19 Size Switch PWB

Parts List on PL 13.3
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Feeder Rear Cover.
NOTE: Note the positioning of the bracket prior to removing it.
3.
Remove the Size Switch PWB. (Figure 1)
2
Disconnect the
connector
3
Remove the screw and
the Size Switch PWB
Figure 1 Removing the Size Switch PWB
Initial Issue
Phaser 790/DocuColor 2006
WARNING
1
Remove two
screws and the
Bracket
Typical
Replacement
1.
Perform the removal procedure in reverse.
2.
Return the bracket to the exact position from which it was removed.