REP 8.41 Full Stack Sensor

Parts List on PL 9.2
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Top Cover Assembly. (REP 14.4)
3.
Remove the Full Stack Sensor. (Figure 1)
Figure 1 Removing the Full Stack Sensor
Replacement
1.
Perform the removal procedure in reverse.
Initial Issue
Phaser 790/DocuColor 2006
WARNING
2
Remove the screw and
Full Stack Sensor
1
Disconnect the
connector

REP 8.42 Exit Chute Interlock

Parts List on PL 9.2
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Exit Transport Assembly. (REP 8.40)
3.
Remove the Exit Chute Interlock. (Figure 1)
Figure 1 Removing the Exit Chute Interlock
Replacement
1.
Perform the removal procedure in reverse.
10/00
4-89
WARNING
2
Release the locking
tabs and remove the
Exit Chute Switch
1
Disconnect the
connector