016-370 IOT to ESS Communication Failure RAP
The Control Logic detected an IOT to ESS communication failure.
Procedure
Perform the following:
•
Switch off the power. Remove the Right Cover in order to access the ESS PWB.
•
Remove and reseat the ESS PWB.
•
Switch on the power. If the problem is still present, replace the ESS PWB (PL 12.1).
•
If the problem continues, replace the MCU PWB (PL 11.2).
Initial Issue
Phaser 790/DocuColor 2006
XX82 Fault Code RAP
The series of fault codes identified with four placeholder fault codes ending withXX82 is
caused by a controller job handling error.
Procedure
Perform the following:
*
Switch off the power and switch on the power.
*
Switch off the power and disconnect the printer from the network.Switch the power on and
clear the job log and queues on the printer and client. Switch off the power and reconnect the
network, switch the power on.
*
Replace the hard drive (PL 12.1)
10/00
2-211