REP 8.40 Exit Transport Assembly
Parts List on PL 9.1
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Top Cover. (REP 14.4)
3.
Remove the Rear Cover. (REP 14.6)
The plastic hinges of the Transport Cover can be easily damaged. Use care when performing
the following step.
4.
Remove the Exit Transport Cover. (Figure 1)
Figure 1 Removing the Transport Cover
Repairs and Adjustments
REP 8.40
WARNING
CAUTION
5.
Remove the Exit Transport Assembly. (Figure 2)
1
Disconnect the
connectors (2)
Figure 2 Removing the Exit Transport Assembly
Replacement
1.
Perform the removal procedure in reverse.
2.
When replacing the Exit Transport Assembly, make sure that the plastic ears at the top
(and at the bottom, below the fan) are positioned over the edge of the frame. (Figure 3)
Figure 3 Exit Transport Assembly Positioning
10/00
4-88
2
Remove the five
screws and the Exit
Transport Assem-
bly as shown
Frame
Edge
Plastic Ears
Initial Issue
Phaser 790/DocuColor 2006