REP 11.7 Sorter Path Sensor

Parts List on PL 19.3
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Bottom Cover (REP 11.2).
3.
Remove the Sorter Path Sensor (Figure 1).
1
Disconnect the connector
Figure 1 Removing the Sorter Path Sensor
Replacement
1.
Perform the procedure for removal in reverse.
Initial Issue
Phaser 790/DocuColor 2006
WARNING
2
Release the locking
tabs and remove the
Sorter Path Sensor
Viewed from below

REP 11.8 Full Sensor

Parts List on PL 19.3
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Bottom Cover (REP 11.2).
3.
Remove the Full Sensor (Figure 1).
1
Disconnect the
connector
Figure 1 Removing the Full Sensor
Replacement
1.
Perform the procedure for removal in reverse.
10/00
4-133
WARNING
3
Remove the screw
and the Full Sensor
2
Remove the screw and
sensor bracket
Repairs and Adjustments