Table 3 Life Counters
Menu No Function
Remarks
7
Printer (2)
Value increments with each
deactuation of the Fuser Exit
Sensor and is multiplied by
the following: for b/w less
than 219 mm in process
length indexes 1. B/w more
than 219 mm advances 2x.
Color less than 219 mm
advances 4x, and longer
than 219 mm advances 8x.
8
Unused
9
BTR 2
Increments the same for
color and for b/w based
upon the deactuation of the
Fuser Exit Sensor. The
value increments 1 for
sheets less than 219 mm in
the process length and 2 if
greater than 219 mm.
10
Belt Cleaner
Increments the same for
color and b/w based upon
the deactuation of the Fuser
Exit Sensor. The value incre-
ments 1 for sheets less than
219 mm in process length,
and 2 if length is greater
than 219 mm.
11
Unused
12
Unused
13
Developer Y
Each TR0 signal increments
the counter by 2, if the color
is required.
14
Developer M
Each TR0 signal increments
the counter by 2, if the color
is required.
15
Developer C
Each TR0 signal increments
the counter by 2, if the color
is required.
16
Developer K
Each TR0 signal increments
the counter by 2, if the color
is required.
20
IBT Belt
Each TR0 signal increments
the counter by 2, if the color
is required.
General Procedures and Information
GP 3
9.
Life / Reset
Provides a cumulative count of
the number of color separa-
tions produced by the system.
Reset is not required or recom-
mended.
Counter must be manually
reset following replacement.
Information was originally
intended to enable replace-
ment at prescribed intervals.
This feature is disabled in this
product.
Counter must be manually
reset following replacement.
Information was originally
intended to enable replace-
ment at prescribed intervals.
This feature is disabled in this
product.
Counter must be manually
reset following replacement.
Counter must be manually
reset following replacement.
Counter must be manually
reset following replacement.
Counter must be manually
reset following replacement.
Counter must be manually
reset following replacement.
03/01
6-10
Press the Menu button to return to DIAG EXIT, and press the Item Enter button to write
to the NVM.