Rep 3.1 Control Pwb; Rep 3.2 High Voltage Power Supply (Hvps) - Xerox 3001 Service Manual

Engineering copier 60/50 hz
Table of Contents

Advertisement

REP 3.1 CONTROL PWB
PARTS LlST ON PL 1.4
REPLACEMENT
AFTER REPLACING THE CONTROL PWB,
PERFORM THE FOLLOWING ADJUSTMENTS:
1. COUNTRY CONFIGURATION (ADJ 3.3).
2.
ELECTROSTATIC SERIES (ADJ 9.2).
3.
REGISTRATION (ADJ 8.
I ) .
4.
LEAD EDGE MARGIN (ADJ 8.2).
5. FUSER TEMPERATURE (ADJ 10.1)
6. TIMEOUT INTERVAL TO REST MODE (ADJ
3.1)
7. TIMEOUT INTERVAL TO POWER SAVER
MODE (ADJ 3.2).
8. COPY SIZE ADJUSTMENT (ADJ 5.1)
9. ENTER DIAGNOSTICS AND ENTER THE
CODE (311. SET THE CORRECT COPIER
CONFIGURATION.
REP 3.2 HIGH VOLTAGE POWER
REPLACEMENT
SUPPLY (HVPS)
PARTS LlST ON PL 1.4
0
Step
3
E in REMOVAL: Ensure that the
screws
are reinstalled for a proper
electrical ground.
REMOVAL
Route all High Voltage wires through the
1. WARNING: DISCONNECTTHE POWER
appropriate cable ties, making sure that
CORD.
the HV vvjres are not stressed against sharp
metal.
2. REMOVE THE LEFT SIDE COVER.
1. PERFORM THE ELECTROSTATIC SERIES (ADJ
3. (FIGURE 1): REMOVE THE HIGH VOLTAGE
9.2).
POWER SUPPLY (HVPS).
UNPLUG J24
REMOVE HVPS
UNPLUG RED
AND BLUE
CONNECTORS
UNPLUG GREEN AND
ORANGE CONNECTORS
UNPLUG J25
-
1 2/98