001-708 Area 3 Open RAP

Initial Actions
Perform the following:
Ensure the Right Cover is fully closed.
Check the actuators for both Feeder Right Cover Switches. Ensure they are not broken or
damaged.
Procedure
Access the Digital Input (DI) test from the Control Panel. Enter code [C0]. Press the Item/Enter
button. The display indicates 0.
Y
N
Remove the Feeder Rear Cover (PL 13.2). Less than +1.0 VDC is measured between
J217-8 on the Feeder PWB and machine frame.
Y
N
Go to Flag 1. Check the wires for an open circuit. If the wires are good, replace the
Feeder Right Cover Interlock 1 (PL 13.2).
Replace the Feeder PWB (PL 13.4).
Enter code [C1]. Press the Item/Enter button. The display indicates 0.
Y
N
Remove the Feeder Rear Cover. Less than +1.0 VDC is measured between J217-10
on the Feeder PWB and machine frame.
Y
N
Go to Flag 2. Check the wires for an open circuit. If the wires are good, replace the
Feeder Right Cover Interlock 2 (PL 13.2).
Replace the Feeder PWB (PL 13.4).
The problem may be intermittent. Go to Figure 1 and check for loose or damaged connections
or damaged wires. If the problem persists, replace the Feeder Right Cover Interlock 1 and 2
(PL 13.2). If the problem continues, replace the Feeder PWB (PL 13.4).