REP 8.6 Bypass Tray/Registration Assembly
Parts List on PL 4.1
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Bypass Tray/Registration Assembly. (Figure 1)
Figure 1 Removing the Bypass Tray/Registration Assembly
Replacement
1.
Perform the procedure for removal in reverse.
Repairs and Adjustments
REP 8.6, REP 8.7
WARNING
1
Remove the two screws securing
the Bypass Tray/Registration
Assembly to the front and rear
rails and remove the assembly
by pulling it straight out
REP 8.7 Bypass Tray Feed Assembly
Parts List on PL 4.1
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Bypass Tray/Registration Assembly. (REP 8.6)
The Bypass Tray Feed Assembly and Base Assembly are connected by a harness. Be careful
not cause damage to the wires when performing the following.
3.
Remove the Bypass Tray Feed Assembly. (Figure 1)
1
Remove four screws
Bypass Tray
Feed Assembly
Figure 1 Accessing the Bypass Tray Feed Assembly
Replacement
1.
Perform the procedure for removal in reverse.
10/00
4-64
WARNING
CAUTION
3
See Caution - Lift
the Feed Assem-
bly and turn it on its
harness, so it is
facing bottom-side-
up next to the Base
Assembly
Base Assembly
2
Remove the two screws securing
the Bypass Tray Feed Assembly
Phaser 790/DocuColor 2006
Initial Issue