Adj 6.3 Iit Lead Edge Registration - Xerox Phaser 790 Service Manual

Hide thumbs Also See for Phaser 790:
Table of Contents

Advertisement

ADJ 6.3 IIT Lead Edge Registration

Purpose
The purpose is to achieve the proper home position in the IIT lead edge (slow scan) direction.
IIT lead edge registration affects the entire accuracy regarding document size detection and
other document positions.
Check
1.
Using the Copier Setup Test Pattern 82E8220, make two copies with the machine set to
Tray 1, A3, and 100% magnification.
2.
Check the second copy. Verify that the distance from the lead edge of the copy to the indi-
cated point is 10±2.0mm. (Figure 1)
10.0mm ± 2.0
Paper
Feed
Direction
Figure 1 Test Pattern Indications
Adjustment
1.
Enter Diagnostic Mode (IIT) (GP 19).
Initial Issue
Phaser 790/DocuColor 2006
Lead Edge
2.
Enter Systemdata R/W and press the Select button.
3.
Enter Chain 715 and Link 3 and confirm the present values.
4.
Change the values as required, based on the measurement results (Figure 1). When the
measurement is short, reduce the value; when the measurement is long, increase the
value. Change the values as follows:
NOTE: To enter a letter Hexadecimal value, press the asterisk key prior to entering each letter
value, then press the appropriate numerical key as follows: A=1, B=2, C=3, D=4, E=5,
F=6
a.
Enter the new value and press Start.
b.
Press the Select button to verify the value has changed.
Minimum
Settings Range
1
5.
Perform the check again.
10/00
4-157
Table 1
Initial
Maximum
Remarks
47h
FFh
0.04mm/Step
Repairs and Adjustments