REP 9.13 Cartridge Sensor

Parts List on PL 6.1
Removal
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1.
Switch off the machine power and disconnect the machine Power Cord.
2.
Remove the Top Cover Assembly (REP 14.4).
3.
Access the Cartridge Sensor (Figure 1).
2
Disengage the wires from the hook
on the Cartridge Sensor Plate
1
Disconnect the con-
nector
Figure 1 Accessing the Cartridge Sensor
Repairs and Adjustments
REP 9.13
WARNING
4.
Remove the Cartridge Sensor (Figure 2).
Replacement
Securely route the harness in the hooks of the Sensor Plate and Rotary Latch so there is no
slack in the harness.
1.
Reinstall the Cartridge Sensor in the reverse order of removal.
3
Remove the Cartridge
Sensor
2
Remove the
screw securing
the sensor
Figure 2 Removing the Cartridge Sensor
10/00
4-102
CAUTION
1
Remove the screw
securing the Car-
tridge Sensor Plate