033-210 Printer Detection RAP
Connection with the printer failed.
Procedure
Switch off the power, then switch on the power. If the fault is still present, replace the ICM Main
PWB (PL 16.2).
Initial Issue
Phaser 790/DocuColor 2006

033-211/212 IOT/IIT Disconnection RAP

033-211: The Control Logic detects a disconnection.
033-212: The Control Logic detects no printer.
Initial Actions
Check the cables and connections between the IIT and the IOT. Ensure that the cables are
secure.
Exit, then re-enter the Copy mode. if this does not resolve the problem, switch the power off
then on. Verify that the problem still exists.
Procedure
Remove the Right Cover (REP 14.9). Verify that the 1394 PWB is correctly installed. If the
PWB is installed correctly and the problem still exists, replace the 1394 PWB (PL 12.1). If the
problem continues, replace the ICM Main PWB (PL 16.2).
10/00
2-213
Status Indicator RAPs
033-210, 033-211/212