Selection of operation mode and operation location
Operation mode basics
The operation mode is to specify the source of inputting the start command and set frequency
of the inverter.
● Select the "external operation mode" when performing operation by basically using the
control circuit terminals and providing potentiometers, switches, etc. externally.
● Select the "PU operation mode" when inputting the start command and frequency setting
through communication from the operation panel (FR-DU07), parameter unit (FR-PU04/FR-
PU07) or PU connector.
● Select the "network operation mode (NET operation mode)" when using the RS-485
terminals or communication option.
The operation mode can be selected from the operation panel or with the communication
instruction code.
Fig. 6-202: Operation modes of the inverter
NOTES
Either "3" or "4" may be set to select the PU/external combined operation, and these settings
differ in starting method.
In the initial setting, the stop function by of the PU (FR-DU07) (PU stop selection) is valid
also in other than the PU operation mode. (Refer to Pr. 75 "Reset selection/disconnected PU
detection/PU stop selection".)