Mitsubishi Electric FR-A700 Instruction Manual page 461

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Parameter
● Orientation from the forward rotation direction
This method is used to improve the stopping precision and maintain the mechanical precision
when the backlash is large.
If the motor is running in the forward rotation direction, it will make an orientation stop with the
same method as "orientation from the current rotation direction".
If the motor is running in reverse, it will decelerate, the rotation direction will be changed to for-
ward run, and then orientation stop will be executed.
(forward rotation)
(reverse rotation)
● Orientation from the reverse rotation direction
If the motor is running in the reverse rotation direction, it will make an orientation stop with the
same method as "orientation from the current rotation direction".
If the motor is running in forward, it will decelerate, the rotation direction will be changed to
reverse run, and then orientation stop will be executed.
(forward rotation)
(reverse rotation)
FR-A700 EC
Speed
X22
OFF
ON
ORA
OFF
Speed
X22
OFF
ON
ORA
OFF
Speed
X22
OFF
ON
ORA
OFF
Speed
X22
OFF
ON
ORA
OFF
Fig. 6-120:
Orientation from the forward rotation direction
Time
ON
Time
ON
Fig. 6-121:
Orientation from the reverse rotation direction
Time
ON
Time
ON
Motor brake and stop operation