Motor brake and stop operation
NOTES
The RUN signal turns off when the output stops.
Stop selection is invalid when the following functions are activated.
Position control (Pr. 419 = 0)
Power failure stop function (Pr. 261)
PU stop (Pr. 75)
Deceleration stop because of fault definition (Pr. 875)
Deceleration stop because of communication error (Pr. 502)
Offline auto tuning (with motor running)
Emergency stop by LonWorks communication
When the start signal is turned on again during motor coasting, the motor starts at Pr. 13
"Starting frequency".
6 - 256
Parameter