Parameter overview
Parameter
Func-
Name
tion
PU communication
117
station
PU communication
118
speed
PU communication
119
stop bit length.
PU communication
120
parity check
Number of PU commu-
121
nication retries
PU communication
122
check time interval
PU communication
123
waiting time setting
Tab. 6-1:
Parameter overview (28)
6 - 28
Incre-
Initial
Setting
ments
Value
Range
1
0
0–31
48/96/
1
192
192/384
0
1
1
1
10
11
0
1
2
1
2
0–10
1
1
9999
0
0.1s
9999
0.1–999.8s
9999
0–150ms
1
9999
9999
Description
Specify the inverter station
number. Set the inverter station
numbers when two or more invert-
ers are connected to one personal
computer.
Set the communication speed. The
setting value × 100 equals the
communication speed.
For example, the communication
speed is 19200bps when the set-
ting value is "192".
Stop bit length: 1bit
data length: 8bit
Stop bit length: 2bit
data length: 8bit
Stop bit length: 1bit
data length: 7bit
Stop bit length: 2bit
data length: 7bit
Without parity check
With odd parity check
With even parity check
Set the permissible number of
retries at occurrence of a data
receive error. If the number of
consecutive errors exceeds the
permissible value, the inverter will
come to an alarm stop.
If a communication error occurs,
the inverter will not come to an
alarm stop.
No PU connector communication
Set the communication check time
interval. If a no-communication
state persists for longer than the
permissible time, the inverter will
come to an alarm stop.
No communication check
Set the waiting time between data
transmission to the inverter and
response.
Set with communication data.