Mitsubishi Electric FR-A700 Instruction Manual page 233

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Parameter
Parameter
Func-
Name
tion
503
Maintenance timer
Maintenance timer
504
alarm output set time
505
Siehe Pr. 37
516
Siehe Pr. 29
519
USB communication
547
station number
USB communication
548
check time interval
Refer to Pr. 338 and Pr. 339
551
549
Refer to Pr. 117
550
Refer to Pr. 338 and Pr. 339
551
555
Current average time
556
Data output mask time
Current average value
557
monitor signal output
reference current
Tab. 6-1:
Parameter overview (53)
FR-A700 EC
Incre-
Initial
Setting
ments
Value
Range
1
0
0 (1–9998)
0–9998
1
9999
9999
1
0
0–31
0
0.1s
9999
0.1–999.8s
9999
0.1s
1s
0.1–1.0s
0.1s
0s
0.0–20.0s
Rated
0.01/
0–500/
inverter
0.1A *
0–3600A *
current
Description
Display the cumulative energizing
time of the inverter in 100h incre-
ments. Reading only
Writing the setting of "0" clears the
cumulative energizing time.
Set the time taken until when the
maintenance timer alarm output
signal (Y95) is output.
No Function
Specify the inverter station
number.
USB communication is enabled.
However, the inverter will come to
an alarm stop (E.USB) if operation
is changed to PU operation mode.
Set the interval of communication
check time.
No communication check
Set the time taken to average the
current during start bit output
(1s).
Set the time for not obtaining
(mask) transient state data.
Set the reference (100%) for out-
putting the signal of the current
average value
* Setting increments and setting
range differ according to the
inverter capacity:
(01800 or less/02160 or more)
Parameter overview
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled
6-531
6-487
6-532
6 - 53