Parameter
You can select the decimal digits of the monitor (Pr. 268)
As the operation panel (FR-DU07) display is 4 digits long, the decimal places may vary at analog
input, etc. The decimal places can be hidden by selecting the decimal digits. In such a case, the
decimal digits can be selected by Pr. 268.
9999 (initial value)
Tab. 6-96: Selection of decimal digits
NOTE
The number of display digits on the cumulative energizing time (Pr. 52 = 20), actual opera-
tion time (Pr. 52 = 23), cumulative energizing power (Pr. 52 = 25) or cumulative saving
power monitor (Pr. 52 = 51) does not change.
FR-A700 EC
Pr. 268
Description
No function
When 1 or 2 decimal places (0.1 increments or 0.01 increments) are monitored,
the decimal places are dropped and the monitor displays an integer value
0
(1 increments).
The monitor value of 0.99 or less is displayed as 0.
When 2 decimal places (0.01 increments) are monitored, the 0.01 decimal place
is dropped and the monitor displays the first decimal place (0.1 increments).
1
When the monitor display digit is originally in 1 increments, it is displayed
unchanged in 1 increments.
Monitor display and monitor output signals
6 - 329