Acceleration and deceleration
S-pattern acceleration/deceleration C (Pr. 29 = 4, Pr. 380 to Pr. 383)
With the S-pattern acceleration/deceleration C switch signal (X20), an acceleration/decelera-
tion curve S-pattern 1 or S-pattern 2 can be selected. For the terminal used for X20 signal input,
set "20" in any of Pr. 178 to Pr. 189 (input terminal function selection) to assign the function.
Abb. 6-84: Characteristic for parameter 29 = 4
Tab. 6-41: Selection of acceleration/deceleration curve S-pattern 1 or S-pattern 2
Set % of time taken for forming an S-pattern in Pr. 380 to Pr.383 as acceleration time is 100%.
Parameter setting [%]
6 - 204
Frequency
Output frequency
Set
frequency
Switch
signal
OFF
X20
X20
During Acceleration
AUS
Pr. 380 Acceleration S-pattern 1
EIN
Pr. 382 Acceleration S-pattern 2
Ts
×
----- -
=
T
S-pattern
acceleration
Ts
Ts
T
Pr. 382
Pr. 380
ON
OFF
100 %
Abb. 6-85:
Parameter setting
Linear
acceleration
Pr. 381
Pr. 383
ON
During Deceleration
Pr. 381 Deceleration S-pattern 1
Pr. 383 Deceleration S-pattern 2
Parameter
Time