Forward/reverse signal
NOTES
When Pr. 250 is set to any of "0 to 100, 1000 to 1100", the motor coasts to a stop if the start
command is turned off. (Refer to section 6.13.3.)
The STF and STR signals are assigned to the STF and STR terminals in the initial setting.
The STF signal can be assigned to Pr. 178 "STF terminal function selection" and the STR
signal to Pr. 179 "STR terminal function selection" only.
Changing the terminal assignment using Pr. 178 to Pr. 189 "Input terminal function
selection" may affect the other functions. Please make setting after confirming the function of
each terminal.
FR-A700 EC
Inverter
Start signal
ON
ON
Function assignment of external terminals
Fig. 6-128:
2-wire type connection (Pr. 250 = 8888)
Time
I001149E