Parameter
Parameter
Func-
Name
tion
C0
CA terminal calibration
(900)
C1
AM terminal calibration
(901)
C2
(902)
Refer to Pr. 125 and Pr. 126
C7
(905)
Current output bias
C8
(930)
signal
Current output bias
C9
(930)
current
Current output gain
C10
(931)
signal
Current output gain
C11
(931)
current
Terminal 1 bias fre-
C12
(917)
quency (speed)
C13
Terminal 1 bias (speed)
(917)
Terminal 1 gain fre-
C14
(918)
quency (speed)
Terminal 1 gain
C15
(918)
(speed)
Terminal 1 bias com-
C16
mand (torque/mag-
(919)
netic flux)
Terminal 1 bias
C17
(919)
(torque/magnetic flux)
Terminal 1 gain com-
C18
mand (torque/mag-
(920)
netic flux)
Terminal 1 gain
C19
(920)
(torque/magnetic flux)
Tab. 6-1:
Parameter overview (63)
FR-A700 EC
Incre-
Initial
Setting
ments
Value
Range
0.1%
0%
0–100%
0.1%
0%
0–100%
0.1%
100%
0–100%
0.1%
100%
0–100%
0.01Hz
0Hz
0–400Hz
0.1%
0%
0–300%
0.01Hz
50Hz
0–400Hz
0.1%
100%
0–300%
0.1%
0%
0–400%
0.1%
0%
0–300%
0.1%
150%
0–400%
0.1%
100%
0–300%
Description
Calibrate the scale of the meter
connected to terminal CA.
Calibrate the scale of the analog
meter connected to terminal AM.
Set the output signal value at the
minimum analog current output.
Set the minimum current value at
the minimum analog current out-
put.
Set the output signal value at the
maximum analog current output.
Set the maximum current value at
the maximum analog current out-
put.
Set the frequency on the bias side
of terminal 1 input.
(valid when Pr. 868 = 5)
Set the converted % of the bias
side voltage (current) of terminal 1
input. (valid when Pr. 868 = 5)
Set the frequency of terminal 1
input gain (maximum).
(valid when Pr. 868 = 5)
Set the converted % of the gain
side voltage (current) of terminal 1
input. (valid when Pr. 868 = 5)
Set the torque/magnetic flux com-
mand value on the bias side of ter-
minal 1 input.
(valid when Pr. 868 ≠ 0, 5)
Set the converted % of the bias
side voltage (current) of terminal 1
input. (valid when Pr. 868 ≠ 0, 5)
Set the torque/magnetic flux com-
mand value on the gain side of ter-
minal 1 input.
(valid when Pr. 868 ≠ 0, 5)
Set the converted % of the gain
side voltage (current) of terminal 1
input. (valid when Pr. 868 ≠ 0, 5)
Parameter overview
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled
6-333
6-333
6-382
6 - 63