Mitsubishi Electric FR-A700 Instruction Manual page 523

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Parameter
● Encoder detection frequency search
When "2 or 12" is set in Pr. 162 under encoder feedback control, the motor starts at the
motor speed and in the rotation direction detected from the encoder at power restoration.
Encoder detection frequency search is performed regardless of the Pr. 162 setting under
vector control.
The Pr. 58 and Pr. 299 settings are invalid for encoder detection frequency search.
Power
supply
(L1, L2, L3)
Motor
speed
[r/min]
Output
frequency [Hz]/
Output
voltage [V]
The output shut off timing differs according to the load condition.
NOTE
When encoder feedback control is invalid, setting "2 or 12" in Pr. 162 enables frequency
search.
● Restart operation at every start
When Pr. 162 = "10, 11 or 12", automatic restart operation is also performed every start, in addi-
tion to the automatic restart after instantaneous power failure. When Pr. 162 = "0" or "2",auto-
matic restart operation is performed at the first start after power supply-on, but the inverter starts
at the starting frequency at the second time or later.
FR-A700 EC
Power failure
Coasting time
Acceleration time
Pr. 57
Pr. 611
Operation selection at power failure
Fig. 6-161:
Encoder detection frequency search
I001605E
6 - 343

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a740 ecFr-a700 ec

Table of Contents