Motor brake and stop operation
Set frequency when stop-on-contact control (Pr. 270 = 1 or 3) is selected
The following table lists the frequencies set when the input terminals (RH, RM, RL, RT, JOG) are
selected together. Bold frame indicates stop-on-contact control is valid.
Stop-on-contact control is invalid when remote setting function is selected (Pr. 59 = 1 to 3).
RH
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Tab. 6-70: Frequency and combined input signals
NOTE
Changing the terminal function using any of Pr. 178 to Pr. 189 may affect the other func-
tions. Make setting after confirming the function of each terminal.
6 - 260
Input Signal
RM
RL
RT
JOG
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Stop-on
Set Frequency
Contact
Pr. 4 "Multi-speed setting (high speed)"
Pr. 5 "Multi-speed setting (middle speed)"
Pr. 6 "Multi-speed setting (low speed)"
By 0 to 5V (0 to 10V), 4 to 20mA input
Pr. 15 "Jog frequency"
Pr. 26 "Multi-speed setting (speed 6)"
Pr. 25 "Multi-speed setting (speed 5)"
Pr. 4 "Multi-speed setting (high speed)"
Pr. 15 "Jog frequency"
Pr. 24 "Multi-speed setting (speed 4)"
Pr. 5 "Multi-speed setting (middle speed)"
Pr. 15 "Jog frequency"
Valid
Pr. 6 "Multi-speed setting (low speed)"
Pr. 15 "Jog frequency"
Pr. 15 "Jog frequency"
Pr. 15 "Jog frequency"
Pr. 15 "Jog frequency"
Pr. 15 "Jog frequency"
Valid
Pr. 6 "Multi-speed setting (low speed)"
Pr. 15 "Jog frequency"
Pr. 15 "Jog frequency"
Valid
Pr. 6 "Multi-speed setting (low speed)"
Pr. 15 "Jog frequency"
Pr. 26 "Multi-speed setting (speed 6)"
Pr. 27 "Multi-speed setting (speed 7)"
Pr. 15 "Jog frequency"
Pr. 15 "Jog frequency"
Pr. 15 "Jog frequency"
Pr. 15 "Jog frequency"
Valid
Pr. 6 "Multi-speed setting (low speed)"
Pr. 15 "Jog frequency"
By 0 to 5V (0 to 10V), 4 to 20mA input