Misoperation prevention and parameter setting restriction
Pr. 75
0
1
2
3
14
(initial
value)
15
16
17
100
101
102
103
114
115
116
117
Tab. 6-115: Setting of parameter 75
Available with the 02160 or more.
Reset selection
You can select the operation timing of reset function (RES signal, reset command through com-
munication) input.
When Pr. 75 is set to any of "1, 3, 15, 17, 101, 103, 115, 117", a reset can be input only when
the protective function is activated.
NOTES
When the reset signal (RES) is input during operation, the motor coasts since the inverter
being reset shuts off the output. Also, the cumulative value of the electronic thermal relay
function is cleared.
When the RESET signal is applied continuously while the frequency inverter is in an error-
free condition the message "err" will blink in the display.
The reset key of the PU is valid only when the protective function is activated, independently
of the Pr. 75 setting.
6 - 404
Reset Selection
Reset input always enabled.
Enabled only when the protective
function is activated
Reset input always enabled.
Enabled only when the protective
function is activated
Reset input always enabled.
Enabled only when the protective
function is activated
Reset input always enabled.
Enabled only when the protective
function is activated
Reset input always enabled.
Enabled only when the protective
function is activated
Reset input always enabled.
Enabled only when the protective
function is activated
Reset input always enabled.
Enabled only when the protective
function is activated
Reset input always enabled.
Enabled only when the protective
function is activated
Disconnected PU
PU Stop Selection
Detection
If the PU is discon-
nected, operation will be
Pressing the
continued.
STOP key deceler-
ates the motor to a
When the PU is discon-
stop only in the PU
nected, the inverter out-
operation mode.
put is shut off.
If the PU is discon-
Pressing the
STOP key deceler-
nected, operation will be
ates the motor to a
continued.
stop in any of the
PU, external and
When the PU is discon-
communication
nected, the inverter out-
operation modes.
put is shut off.
If the PU is discon-
nected, operation will be
Pressing the
continued.
STOP key deceler-
ates the motor to a
When the PU is discon-
stop only in the PU
nected, the inverter out-
operation mode.
put is shut off.
If the PU is discon-
Pressing the
nected, operation will be
STOP key deceler-
continued.
ates the motor to a
stop in any of the
When the PU is discon-
PU, external and
nected, the inverter out-
communication
put is shut off.
operation modes.
Parameter
Reset Limit
(01800 or more)
No function
Function