Mitsubishi Electric FR-A700 Instruction Manual page 573

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Parameter
Pr. 858
Setting
0
(Initial
value)
1
4
9999
Tab. 6-112: Terminal 4 functional calibration parameter
Use Pr. 148 "Stall prevention level at 0V input" and Pr. 149 "Stall prevention level at 10V
input" to adjust bias/gain of stall prevention operation level.
FR-A700 EC
Frequency/torque setting by analog input (terminals 1, 2 and 4)
Calibration Parameters
Terminal
Function
Bias setting
C5 (Pr. 904)
Frequency
command/
speed
C6 (Pr. 904)
command
Magnetic flux
command
C38 (Pr. 932)
Stall preven-
tion operation
C39 (Pr. 932)
level
/torque
limit
Gain setting
Terminal 4 frequency
Pr. 126
setting bias frequency
Terminal 4 frequency
C7 (Pr. 905)
setting bias
Terminal 4 bias
C40 (Pr. 933)
command (torque/mag-
netic flux)
Terminal 4 bias (torque/
C41 (Pr. 933)
magnetic flux)
Terminal 4 frequency
setting gain frequency
Terminal 4 frequency
setting gain
Terminal 4 gain
command (torque/
magnetic flux)
Terminal 4 gain (torque/
magnetic flux)
6 - 393